Simplex Smoke Detector Removal Tool

Posted on -

Smoke and Carbon Monoxide Alarm, Detection Method Photoelectric, Up to 24 Units Interconnection Capability, Power Source 120VAC, 9V, Audible Alert 85dB @ 10 ft., Horn, Visual Alert Red LED, Diameter 5-3/4 In., Height 1-7/8 In., Width -, Digital Readout No, Battery Backup Yes, Features Interconnectable, Green Power LED, Red Alarm Status LED, Quick Connect Power Harness, End of Life Alarm, Voice Warning, Hush Button Yes, Locking Pin Yes, Operating Temp. 40 Degrees to 100 Degrees F Smoke and Carbon Monoxide Alarm, Detection Method Photoelectric, Up to 24 Units Interconnection Capability. Carbon Monoxide and Gas Alarm, Detection Method Electrochemical, No Interconnection Capability, Power Source 120VAC, 9V, Audible Alert 85dB @ 10 ft., Horn, Visual Alert Red LED, Height 6 In., Depth 1-3/4 In., Width 3-3/4 In., Digital Readout Yes, Battery Backup Yes, Features Direct Plug In, Samples Air Every 2.5 Minutes, Peak Level Memory, Hush Button No, Locking Pin No, Operating Temp. 40 Degrees to 100 Degrees F, Standards IAS6 to 96, UL2034, Manufacturers Warranty Length 7 Year Limited Carbon Monoxide and Gas Alarm, Detection Method Electrochemical, No Interconnection Capability, Power Source. Heat Alarm, Detection Method Thermistor, Yes Interconnection Capability, Power Source 120VAC, 9V, Audible Alert 85dB @ 10 ft., Horn, Visual Alert Red LED, Diameter 5 In., Height 2 In., Digital Readout No, Battery Backup Yes, Features Interconnectable to Smoke Alarms for Protection of Garages and Attics, Hush Button No, Locking Pin Yes, Operating Temp.20 Degrees to 100 Degrees F, Standards UL 217, Manufacturers Warranty Length 10 yr. Heat Alarm, Detection Method Thermistor, Yes Interconnection Capability, Power Source 120VAC, 9V, Audible. Heat Alarm, Detection Method Thermistor, Up to 18 Units Interconnection Capability, Power Source 120VAC, 9V, Audible Alert 85dB @ 10 ft., Audio, Visual Alert Red LED, Diameter 5-1/2 In., Height 2-1/4 In., Width -, Digital Readout No, Battery Backup Yes, Hush Button Yes, Locking Pin Yes, Operating Temp.10 Degrees to 135 Degrees F, Standards UL539, Manufacturers Warranty Length 10 Year Limited Heat Alarm, Detection Method Thermistor, Up to 18 Units Interconnection Capability, Power Source 120VAC, 9V.

Smoke and/or heat sensing with physical protection. Screw Removal Tool: 4098-9823 Secure Hex Key. Detector shall be listed for use with the detector.”. Silent Knight XR2B TOOLS; TOOL Removal/replacement for current models of the 100 and 200 series plug-in smoke detectors. Silent Knight; Code: SKN-XR2B.

Smoke Alarm, Detection Method Ionization, Photoelectric, Yes Interconnection Capability, Power Source 120V, Audible Alert Beep, Visual Alert Flashing Light, Height 6 In., Depth 2 In., Width 4 In., Digital Readout No, Battery Backup Yes, Features Low Frequency Beep Sound, Hush Button No, Locking Pin No, Operating Temp. 32 Degrees to 120 Degrees F, Standards ETL, UL 217, UL 1971, Includes Bed Shaker, Power Cord, Batteries, Instruction Manual, Manufacturers Warranty Length 2 yr. Smoke Alarm, Detection Method Ionization, Photoelectric, Yes Interconnection Capability, Power Source 120V. Carbon Monoxide Alarm, Detection Method Electrochemical, No Interconnection Capability, Power Source 110VAC/DC, Audible Alert 85dB, Visual Alert Red LED, Diameter 3 In. X 5-39/64 In.

X 1-1/2 In., Height 5-39/64 In., Depth 1-1/2 In., Width 3 In., Digital Readout Yes, Battery Backup Yes, Features Direct Plug In, Auto-Dim Display, Hush Button Yes, Locking Pin No, Operating Temp. 40 Degrees to 100 Degrees F, Standards UL, Includes Sealed Lithium Battery, Manufacturers Warranty Length 10 yr. Carbon Monoxide Alarm, Detection Method Electrochemical, No Interconnection Capability, Power Source.

Carbon Monoxide and Gas Alarm, Detection Method Semiconductor, No Interconnection Capability, Power Source 120VAC, Audible Alert 85dB @ 10 ft., Horn, Visual Alert Red LED, Height 2 In., Depth 1-1/4 In., Width 6 In., Digital Readout No, Battery Backup No, Features Direct Plug In, (2) Self-Cleaning Sensors That Operate Independently of Each Other, Hush Button Yes, Locking Pin Yes, Operating Temp.40 Degrees to 150 Degrees F (-40 Degrees to 66 Degrees C), Standards UL 2034, UL 1484 Carbon Monoxide and Gas Alarm, Detection Method Semiconductor, No Interconnection Capability, Power Source. Smoke Alarm, Detection Method Photoelectric, Electrochemical, No Interconnection Capability, Power Source Sealed Lithium Ion, Audible Alert 85dB, Visual Alert Red LED, Diameter 5-7/32 In., Height 5-15/64 In., Depth 1-39/64 In., Width 5-15/64 In., Digital Readout No, Battery Backup Yes, Features Voice Alarm, Hush Button Yes, Locking Pin No, Operating Temp. 40 Degrees to 100 Degrees F, Standards UL, Manufacturers Warranty Length 10 yr.

Smoke Alarm, Detection Method Photoelectric, Electrochemical, No Interconnection Capability, Power Source. Carbon Monoxide Alarm, Detection Method Electrochemical, No Interconnection Capability, Power Source 110VAC/DC, Audible Alert 85dB, Visual Alert Red LED, Diameter 3 In. X 5-39/64 In.

X 1-1/2 In., Height 5-39/64 In., Depth 1-1/2 In., Width 3 In., Digital Readout Yes, Battery Backup Yes, Features Direct Plug In, No Night Chirps, Hush Button Yes, Locking Pin No, Operating Temp. 40 Degrees to 100 Degrees F, Standards UL, Manufacturers Warranty Length 10 yr. Carbon Monoxide Alarm, Detection Method Electrochemical, No Interconnection Capability, Power Source. Smoke Alarm, Detection Method Photoelectric, Yes Interconnection Capability, Power Source 120VAC, 3V, Audible Alert 85dB @ 10 ft., Horn, Visual Alert Red LED, Diameter 5-13/64 In., Height 5-13/64 In., Depth 2-19/64 In., Width 5-13/64 In., Digital Readout No, Battery Backup Yes, Features Alarm Latch, Low Battery Latch, Low Battery Silence and Alarm Silence, Strobe Light, Hush Button Yes, Locking Pin No, Operating Temp. 40 Degrees to 100 Degrees F, Standards UL STD 217, UL STD 1971 Smoke Alarm, Detection Method Photoelectric, Yes Interconnection Capability, Power Source 120VAC, 3V, Audible.

Carbon Monoxide and Gas Alarm, Detection Method Electrochemical, No Interconnection Capability, Power Source 120VAC, (2) AA, Audible Alert 85dB @ 10 ft., Horn, Visual Alert Digital display, Diameter 3-7/64 In., Height 5-39/64 In., Depth 1-13/16 In., Width 3-7/64 In., Digital Readout Yes, Battery Backup Y, Features Three Way Protection, Battery Backup, Front Access Battery Compartment, End of Life Timer,Test/Silence Button, Low Battery Warning, Hush Button Yes, Locking Pin No Carbon Monoxide and Gas Alarm, Detection Method Electrochemical, No Interconnection Capability, Power Source. Smoke and Carbon Monoxide Alarm, Detection Method Ionization, Electrochemical, No Interconnection Capability, Power Source (2) AA, Audible Alert 85dB, Visual Alert Red LED, Diameter 5-7/32 In., Height 5-15/64 In., Depth 1-13/16 In., Width 5-39/64 In., Digital Readout No, Battery Backup Yes, Features Voice Alarm, Hush Button Yes, Locking Pin No, Operating Temp.

40 Degrees to 100 Degrees F, Standards UL, Manufacturers Warranty Length 10 yr. Smoke and Carbon Monoxide Alarm, Detection Method Ionization, Electrochemical, No Interconnection Capability. Carbon Monoxide Alarm, Detection Method Electrochemical, No Interconnection Capability, Power Source 12/24 VDC, Four-Wire, Audible Alert 85dB, Visual Alert Red LED, Diameter 6 In., Height 1-19/64 In., Digital Readout No, Battery Backup No, Features Six Year End-Of-Life Timer, Low Current Draw of 20mA in Standby and 40mA in Alarm, Full UL 2075 Compliance, Hush Button Yes, Locking Pin No, Operating Temp. 32 Degrees to 104 Degrees F, Standards UL, CSFM, Manufacturers Warranty Length 3 yr. Carbon Monoxide Alarm, Detection Method Electrochemical, No Interconnection Capability, Power Source 12/24.

Smoke and Carbon Monoxide Alarm, Detection Method Photoelectric, Electrochemical, No Interconnection Capability, Power Source 3V Lithium, Audible Alert 85dB @ 10 ft., Visual Alert No, Diameter 5-43/64 In., Height 5-43/64 In., Depth 1 In., Width 5-43/64 In., Digital Readout No, Battery Backup N, Features 2 In 1 Protection, 10 Year Sealed Lithium Battery, Low Profile, Round Design, Alarm Status LED Indicator, End of Life Signal, Test/Silence Button, Hush Button Yes, Locking Pin Yes. Only shipped in quantities of 3. Smoke and Carbon Monoxide Alarm, Detection Method Photoelectric, Electrochemical, No Interconnection. Smoke Alarm, Detection Method Photoelectric, No Interconnection Capability, Power Source 9V Lithium, Audible Alert 85dB at 10 ft., Diameter 5-13/64 In., Height 1-9/64 In., Depth 1-1/8 In., Width 5-13/64 In., Digital Readout No, Battery Backup No, Features Low Profile Design, Photoelectric, Silence Feature, Tamper Resistant, Hush Button Yes, Locking Pin Yes, Operating Temp.

40 Degrees to 100 Degrees F, Standards UL217, CSFM, NFPA 72,NFPA 101, ICC, Includes Batteries Smoke Alarm, Detection Method Photoelectric, No Interconnection Capability, Power Source 9V Lithium, Audible. Smoke Alarm, Detection Method Photoelectric, No Interconnection Capability, Power Source 9V Alkaline, Audible Alert 85dB at 10 ft., Diameter 5-13/64 In., Height 1-9/64 In., Depth 1-1/8 In., Width 5-13/64 In., Digital Readout No, Battery Backup No, Features Low Profile Design, Photoelectric, Silence Feature, Tamper Resistant, Hush Button Yes, Locking Pin Yes, Operating Temp. 40 Degrees to 100 Degrees F, Standards UL217, CSFM, NFPA 72,NFPA 101, ICC, Includes Batteries Smoke Alarm, Detection Method Photoelectric, No Interconnection Capability, Power Source 9V Alkaline, Audible.

Read 2098-9201+Installation+Manual.pdf text version SSimplex GENERAL INFORMATION 2098-9201, -9203, & -9208 Photoelectric Detectors, 2098-9202 Photo w/Heat Detector, and 2098-9576 Ionization Detector Installation Instructions Before installing there detectors, make a survey of the area to be covered in accordance with information provided in NFPA 72 E, Sections 4-l through 4-6 (an overview of which is provided below). For specific applications, refer to Simplex publication 'Common Code Requirements For Fire Alarm Systems' - Publication No. For additional information, refer to NFPA 72 E and the NEMA Guide For Proper Use of System Smoke Detectors. SPECIAL CONSIDERATIONS l l l l l l l l l l l Is there human occupancy? Contents to be protected. Type of construction and use. Burning characteristics of contents.

Air movement - stratification. Deflections and obstructions. Height of ceilings. Surface conditions of ceilings. Type of ceiling construction. Vent locations - velocities - dilution.

APPLICATIONS Each detector is capable of providing from 450 to 900 square feet (42 to 84 square meters) of coverage, depending on: 1. Requirements of local codes. Results of engineering evaluation. Physical characteristics of protected area. Smooth, flat ceiling Detectors may bespaced30 feet (9 meters) apart. Ceiling divided by beams of more than 18 in. (46 cm) depth At least one detector will be required in the space between every two beam.

Ceiling divided by beams of more than 8 in. (20 cm) but less than 18 in. (46 cm) depth Reduce the coverage area for each detector, and mount the detector to the bottom of the beams.

L l l Important Smoke must enter the chamber of the detector. Thus, air flow, air stratification, air velocity, air stagnation, and air migration will affect detector efficiency. Therefore: Do not install detectors in areas where temperatures are likely to exceed 100°F (38°C) or fall below 32°F (0°C). Do not install detectors on a ceiling within 4 inches (10 cm) of a wall. Do not install detectors where forced air ventilation may dilute the smoke before it reaches the detector.

Do not install detectors in areas where smoke is normally present (kitchens, furnace rooms, laundry rooms, loading docks, rooms with fireplaces, rooms with candles, soldering rooms, etc.). L l l l Suffix 'C'following an 8-digit Product ID number denotes ULC-listed product. Co., Ltd., Mississauga, Ontario L4V 1H3 Canada and are subject to change without notice. Q 1993 Simplex Time Recorder Co.

Gardner, D 1993 Simplex International Time Equipment All specifications and other information Technical Manuals Online! - shown were current as of publication, PER-21 -007 (575285) Ed 2 93 l l l l Do not install detectors in areas where there is likely to be steam (in hospital patient rooms with vaporizers, near shower rooms, above large sinks, etc.). Do not install detectors above ashtrays in elevator lobbies. Wall-mounted detectors should be located 4 to 12 inches (1O-30.5 cm) from the ceiling to detector head. Protect all detector heads during construction to avoid infiltration of construction debris! MAINTENANCE The minimal requirement for detector maintenance should consist of cleaning surface dust by using a vacuum cleaner. Cleaning programs should comply with NFPA and local environments.

Cleaning of the internal chamber should be done by Simplex technical representative only. TEST EQUIPMENT AVAILABLE 2098-9822 (553-394) Extendable Smoke Generator 2098-9809 (553-533) Sensitivity Tester 2098-9814 (553-536) Test and Removal Tool (for use with 2098-9201, -9202, -9203, & -9576) 2098-9815 (553-553) Test and Removal Tool Holder (for use with 553-536 & 553574) (553-574) Test and Removal Tool (for use with 2098-9208) TESTING Before testing, disconnect city, release devices, and extinguish systems. Notify all appropriate personnel of test. The preferred test is with smoke using a 553-394 Extendable Smoke Generator. If this method is not acceptable or practical, a functional test can be performed by using a Test and Removal Tool. To test the detector, place the test tool around the detector body.

This will alarm the detector. To clear the detector, remove the test tool and reset the fire alarm panel.

TABLE 1 SPECIFICATIONS 1 SMOKE DETECTOR DATA Detector Type of Detector Working Voltage (2-Wire) 2098-9576 Ionization 15-36.3 VDC 17.7-33.0 VDC 2098-9201 Photoelectric 15-36.3 VDC 17.7-33.0 VDC 2098-9202 Photoelectric with Heat 15-36.3 VDC 17.7-33.0 VDC 2098-9203 Photoelectric 15-36.3 VDC 17.7-33.0 VDC t2098-9208 Photoelectric 15-32 VDC 17.7-33.0 VDC Filtered DC t Filtered DC. Filtered DC. Filtered DC. Filtered DC.

18V Ripple Max. 18V Ripple Max. 18V Ripple Max. 18V Ripple Max.

18V Ripple Max. 86 mA 86 mA 86 mA 86 mA 86 mA Max. Alarm Current 200 uA 200 uA 200 uA 200 uA 200 uA Surge Current 40 uA 40 uA 40 uA 40 uA 50 uA Standby Current I I I I N/A N/A N/A N/A 1 135 Degrees F 1 Heat Element Rating. Compatibility 2098-9203 2098-9208 2098-9201 2098-9202 2098-9576 Identifier Magnet or Magnet or 5yg;y Test Procedure I y5tj$n$,r y5y;;,o 553-536 553-536 Max.

Barnett s bicycle repair manual. Per See Table 4 See Table 4 See Table 4 See Table 4 See Table 4 Initiating Circuit Voltage Waveform t CAUTION: l Do not use the 2098-9208 detector with the 2098-9734 power pack. The 2098-9208 does not operate from a full wave, rectified (unfiltered) DC power source.When using 2098-9536 four-wire base, full wave, rectified DC can be used. Compatibility identifier is the PID (model number) found on the panel or module and detector base. 2 Technical Manuals Online! - I BASE 3 l/2' OCTAGONAL Yes Yes Yes TABLE 2 BOX MOUNTING 1 4' OCTAGONAL Yes Yes Yes 1 4' SQUARE Yes Yes No 4' (10.16 CM) Outlet Not Furnished Wire per NEC Octagonal Box by Simplex Article 370 2098-9211 Base 2098-9536 2098-9637 Base 2098-9201, 2098.9203, OR 2098-9576 Detector 2098-9202 Detector 2098-9208 TABLE 3 INITIATING CIRCUITS OR PANEL PID IMODEL NO.) TABLE 4 DEHTEEACoTsoR MAX. OF BASES PER INITIATING CIRCUIT 2098-9211 2098-9201, 2098-9202, 2098-9203, 2098-9208, 2098qr9211 with 2098-9738 209&827 2098-9637 2098:637 with 2098-9738 209&827 Notes 1.

(SeeTable?kd Note5 2120-7012 2120-7013 2120-7014 2120-7015 2120-7019 2120-7023 2120-7024 2120-7031 2120-7032 2120-7033 4002-5001 4002-5002 4002-5003 4002-5004 4020-0305 4020-7003 4100-5001 4100-5002 4100-5011 4100-5012 (See Aotel) (SeeTable%md Note5 (See Aote 1) Relay operation cannot be guaranteed unless it is the only device on that zone. Panel compatibility identification marker is the model number of the module or panel. Detector compatibility identification marker is the model number found on the detector label. For detailed interconnection data, see wiring diagrams in Document 841-687.

Exceptions for the maximum quantity of 30 bases per initiating circuit are as follows: lnitiatino Circuit 2120-0523 2120-0527 2120-7011 2120-7022 2120-7805 2120-7806 4001-9403 4001-9404 4001-9813 Qtv. Of Bases 20 20 18 18 25 25 18 18 18 3 Technical Manuals Online! - WARNING Red-labeled detector heads MUST only be used with red-labeled bases. Use in any other base will result in a non-functioning detector.

These heads include /an LED Y Heads 2098-9201, 2098-9202, 2098-9203, OR 2098-9576 ea Head 098-9208 (P-Wire) Base 2098-9637 (4-Wire) Base 2098-9536 CAUTION Install the bases in this instruction in accordance with applicable NFPA standards, local codes, and the authorities having jurisdiction. Failure to follow these instructions may result in failure of the detector to initiate an alarm condition.

Simplex is not responsible for detectors that have been improperly installed, tested, or maintained. CAUTION CONNECT WIRING TO TERMINALS AS SHOWN. DO NOT LOOP WIRE UNDER TERMINALS.

BREAK WIRE RUN TO PROVIDE SUPERVISION OF CONNECTIONS. 4 Technical Manuals Online! - Base - 2098-9536 Head - 2098-9201, 2098-9202, 2098-9203, 2098-9208, or 2098-9576 Base - 2098-9536 Head - 2098-9201, 2098-9202, 2098-9203, 2098-9208, 2098::576 Ll wL2 r Lm3 I Base - 2098-9536 Head - 2098-9201, 2098-9202, 2098-9203, 2098-9208, or 2098-9576 Ll L2.^ 1x1 24 VDC EOL Relay 2098-9735 or 2098-9739 Elk r Ll power source I & i-l L2 Relay 2096-9737 (See Note 3) N/C N/O Note I- -1 2 Blk Elk 1 Note 5 See Notes: 1. Refer to wiring diagrams (841-687) provided with system panel for proper panel connections. If used, remote LED (2098-9808) is polarized; observe color-coded wiring. DO NOT USE RELAY if LED is DO NOT USE REMOTE LED when relay (2098-9737) is used. Alarm contacts -form C-each rated 1A @ 24VDC or 115VAC, resistive.

Alarm contacts - two form C -each rated 3A @ 24VDC or 115VAC, resistive. Refer to wiring diagrams provided with system panel for proper end-of-line resistor value. 2098-9536 BASE CONNECTIONS Backup 2 ISeeNote3 - II ' Primary1 Listed Simplex Fire Alarm Control Panel 2120, 4001,4002, 4020,or4100+ Note 2 see Base - 2098-9637 Head - 2098-9201, 2098-9202, 2098-9203, 2098-9208, 2098qr9576 ' see Note2 RE Base - 2098-9637 Head - 2098-9201, 2098-9202, 2098-9203, 2098-9208, 2096576 Head - 2098-9201, 2098-9202, 2098-9203, 2098-9208, 2092576 Notes: 1. Refer to wiring diagrams (841-687) provided with system panel for proper panel connections. If used, remote LED (2098-9808) is polarized; observe color-coded wiring. It is recommended that the primary-l and the backup-2 lines be in separate wire runs and in compliance requirements.

2098-9637 BASE CONNECTIONS FOR STYLE D (FORMERLY CLASS A) INITIATE CIRCUIT with local 5 Technical Manuals Online! - Listed Simplex Fire Alarm Control Panel 2120, 4001,4002, 1020,or4100+ J 3 Note Head - 2098-9201, 2098-9202, 2098-9203, 2098-9208, 2098qr9578 Head - 20989201, 2098-9202, 2098-9203, 2098-9208, 209E9576 Head - 20989201, 2098-9202, 2098-9203, 2098-9208, 2098qr9576 Notes: 1. Refer to wiring diagrams (841-687) provided with system panel for proper panel connections. If used, remote LED (20989808) is polarized; observe color-coded wiring. Refer to wiring diagrams provided with system panel for proper end-of-line resistor value.

2098-9637 BASE CONNECTIONS FOR STYLE B (FORMERLY CLASS B) INITIATE CIRCUIT Backup 2 rI + I I Primarv 1 c - I I I I I I See Note I I 4 Listed Simplex Fire Alarm Control Panel, 2120, 4001,4002, 4020,or4100+ Aux. Relay Contacts Rated 1 A (1124VDC Or 115VAC Resistive Base - 2098-9637 Relay Module - 2098-9738 Head - 20989201, 2098-9202, 2098-9203, 2098-9208, Or 2098-9738 Relay Module See Note 3 2098-9576 Notes: 1. Refer to wiring diagrams (841-687) provided with system panel for proper panel connections. If used, remote LED (2098-9808) is polarized; observe color-coded wiring. When wiring relay to base, remove resistor (black wire) from base terminal 53.

Wire only one base/relay per initiate circuit. For Style D (formerly Class A) initiate circuit, wire per dotted lines and do not use EOL resistor.

If Style B (formerly Class B) initiate circuit, refer to wiring diagrams provided with system panel for proper EOL resistor value. For Style D (formerly Class A) wiring, it is recommended that the primary-l and the backup-2 lines be in separate wire runs and in compliance with local requirements. 20989637 WITH 20989738 FOR STYLE B (FORMERLY CLASS B) OR STYLE D (FORMERLY CLASS A) INITIATE CIRCUIT BASE AND RELAY CONNECTIONS 6 Technical Manuals Online! - Backup 2 nII II +;I see Note 1 + il -e - Primary 1 Listed Simplex Fire Alarm Control Panel 2120, 4001,4002.

020, or 4100+ Aux. Relay Contacts Rated 1 A ((I 24VDC Or 115VAC Resistive Blk Base - 2098-9211 Relay Module - 2098-9738 Head - 2098-9201, 2098-9202, 2098-9203, 2098-9208, or 2098-9576 2098-9738 Relay Module See Note 3 Notes: 1. Refer to wiring diagrams (841-687) provided with system panel for proper panel connections.

Smoke detector removal tool

If used, remote LED (2098-9808) is polarized; observe color-coded wiring. When wiring relay to base, cut JW. Wire only one base/relay per initiate circuit. For Style D (formerly Class A) initiate circuit, wire per dotted lines and do not use EOL resistor. If Style B (formerly Class B) initiate circuit, refer to wiring diagrams provided with system panel for proper EOL resistor value.

For Style D (formerly Class A) wiring, it is recommended that the primary-l and the backup-2 lines be in separate wire runs and in compliance with local requirements. 2098-9211 WITH 2098-9738 FOR STYLE B (FORMERLY CLASS 8) OR STYLE D (FORMERLY CLASS A) INITIATE CIRCUIT BASE AND RELAY CONNECTIONS zz r Cm Nntr 3 Backup 2 ISeeNote3 r! ' Primary1 Listed Simplex Fire Alarm Control Panel 2120, 4001.4002. 4020, or 4100+ 4 AnSee ^ Red. Note 2 / -s WhtlBlk / Base - 20989211 Head - 2098-9201, 2098-9202, 2098-9203, 20989208, or 2098-9576 Head - 2098-9201, 2098-9202, 2098-9203, 2098-9208, or 2098-9576 Head - 2098-9201, 2098-9202, 2098-9203, 2098-9208, or 2098-9576 Notes: 1. Refer to wiring diagrams (841-687) provided with system panel for proper panel connections. If used, remote LED (2098-9808) is polarized; observe color-coded wiring.

Simplex Smoke Detector Installation Manual

It is recommended that the primary-l and the backup-2 lines be in separate wire runs and in compliance requirements. 2098-9211 BASE CONNECTIONS FOR STYLE D (FORMERLY CLASS A) INITIATE CIRCUIT with local 7 Technical Manuals Online! - See Note 1 i 4 m Listed Simplex Fire Alarm Control Panel 2120, 1001,4002 4020, or 4100+ Base - 2098-9211 Head - 2098-9201. 2098-9202; 2098-9203, 2098-9208, or 2098-9576 Base - 2098-9211 Head - 2098.9201. 2098-9202, 2098-9203, 2098-9208, or 2098-9576 See Note 3 Head - 2098-9201, 2098-9202, 2098-9203, 2098-9208, 209:;576 Notes: 1. Refer to wiring diagrams (841-687) provided with system panel for proper panel connections. If used, remote LED (2098-9808) is polarized; observe color-coded wiring.

Simplex Smoke Detectors

Refer to wiring diagrams provided with system panel for proper end-of-line resistor value. 2098-9211 BASE CONNECTIONS FOR STYLE B (FORMERLY CLASS B) INITIATE CIRCUIT See Note See lote 1 EOL Resistor (if used) Listed Simplex rire Alarm Control Panel 2120, 001,4002, 4020, or 4100+ Red See Note 2 I,;-: Base-2098-9637 Relay Module-2098-9827 Head-2098-9201, 2098-9202, 2098-9203, 2098-9208, or 2098-9576 Aux.

Relay Contacts, Each Rated 1 Amp at 30VDC or 0.5 Amp at 12OVAC, Resistive Notes: 1. I 2098-9827 Relay Module See Note 3 Refer to wiring diagrams (841-687) provided with system panel for proper panel connections. If used, remote LED (2098-9808) is polarized; observe color-coded wiring.

When wiring relay to base, remove resistor (black wire) from base terminal S3. Wire only one base/relay per initiate circuit. For Style D (formerly Class A) initiate circuit. Wire per dotted lines and do not use EOL resistor. If Style B (formerly Class B) initiate circuit, refer to wiring diagrams provided with system panel for proper EOL resistor value. For Style D (formerly Class A) wiring, it is recommended that the primary-l and the backup-2 lines be in separate wire runs and in compliance with local requirements. BASE AND RELAY CONNECTIONS 2098-9637 with 2098-9827 FOR STYLE B (FORMERLY CLASS B) OR STYLE D (FORMERLY CLASS A) INITIATE CIRCUIT a Technical Manuals Online!

- + cm Listed Sim lex FonfrIrnI i Panel 2120, I (+)Red Blk WhtiBlkj ' Vi0 Blu GV. EOL Resistor (if used) 4;204;;2 4106+ Base-2098-9211 Relav Module-2098-9827 Head-20989201, 2098-9202, 2098-9203, 2098-9208, 209:9576 Nii-5 4c -5 N/O Aux. Relay Contacts, Each Rated 1 Amp at 30VDC or 0.5 Amp at 1 POVAC, Resistive Notes: 1.

2098-9827 Relay Module See Note 3 Refer to wiring diagrams (841-687) provided with system panel for proper panel connections. If used, remote LED (2098-9808) is polarized; observe color-coded wiring.

When wiring relay to base, cut JW. Wire only one base/relay per initiate circuit. For Style D (formerly Class A) initiate circuit. Wire per dotted lines and do not use EOL resistor. If Style B (formerly Class B) initiate circuit, refer to wiring diagrams provided with system panel for proper EOL resistor value.

For Style D (formerly Class A) wiring, it is recommended that the primary-l and the backup-2 lines be in separate wire runs and in compliance with local requirements. BASE AND RELAY CONNECTIONS 2098-9211 WITH 20989827 FOR STYLE B (FORMERLY CLASS B) OR STYLE D (FORMERLY CLASS A) INITIATE CIRCUIT LIMITATIONS OF SMOKE DETECTORS The smoke detectors used with these bases are designed to activate and initiate emergency action, but will do so only when used in conjunction with other equipment. They are designed for installation in accordance with NFPA standards 72-l 990 and 72E.

Smoke detectors will not work without power. AC or DC powered smoke detectors will not work if the power supply is cut off for any reason. Smoke detectors will not sense fires which start when smoke does not reach the detectors.

Simplex 4100u Smoke Detector

Smoke from fires in chimneys, in walls, on roofs or on the other side of closed doors may not reach the smoke detector and alarm it. A detector may not detect a fire developing on another level of a building. For this reason, detectors should be located on every level of a building. Smoke detectors have sensing limitations, too. Ionization detectors are better at detecting fast, flaming fires than slow, smoldering fires. Photoelectric detectors sense smoldering fires better than flaming fires.

Because fires develop in different ways, and are often unpredictable in their growth, neither type of detector is always best, and a given detector may not always provide warning of a fire. In general, detectors cannot be expected to provide warning for fires resulting from inadequate fire protection practices, violent explosions, escaping gases, improper storage of flammable liquids like cleaning solvents, other safety hazards, or arson. Smoke detectors cannot last forever. Smoke detectors contain electronic parts. Even though detectors are made to last for many years, any of these parts could fail at any time.

Therefore, test your smoke detector system per NFPA 72E & 72H at least semi-annually. Clean and take care of your smoke detectors regularly. 9 Technical Manuals Online! - Technical Manuals Online! - Technical Manuals Online!

- PER-21 -007 (575285) Ed 2 93 Technical Manuals Online! - http://www.tech-man.com.